ODVA (MPO&MTP) Outdoor Fiber Optic Cable Assemblies
ODVA (MPO & MTP) Outdoor Fiber Optic Cable Assemblies Specification IP37/IP68 outdoor waterproof IP-Series ODVA MPO MTP patch cable Assembly for Multi-purpose Outdoor , For connection between distribution ,Deployment in Remote Radio Head cell towerbox and RRH
Application
- Multi-purpose Outdoor.
- For connection between distribution box and RRH.
- 3.Deployment in Remote Radio Head cell tower
Features
- Cost effective solution for in house termination.
- Low insertion loss and added loss.
- Height of
- IP67 water, dust proof and corrosion resistant
- The material in the jumpel cable are all-weather and UV-resistant.
- Mechanical performance: IEC 61754-7 standard.
- RoHS and REACH materials compliant.
Dimensional Diagrams
- ODVA(MPO&MTP) Outdoor Cable Assemblies
- ODVA(MPO&MTP) Outdoor Cable Assemblies
Patch cord versions
Jumper tolerance requirement | |
Overall length (L) (M) | length of tolerance(CM) |
0<L≤20 | +10/-0 |
20<L≤40 | +15/-0 |
L>40 | +0.5%L/-0 |
Cable Structure
Cable Parameters
Cable Count |
Out sheath Diameter (MM) |
Weight (KG) |
Minimum allowable Tensile Strength (N) | minimum allowable Crush Load
(N/100mm) |
Minimum Bending Radius (MM) |
Storage temperature (℃) |
|||
short term | long term | short term | long term | short term | long term | ||||
8/12/24 | 7.0±0.3 | 35 | 600 | 250 | 800 | 300 | 20D | 10D | -20 ~~ +70 |
Cable Structure
Cable Parameters
Cable Count |
Out sheath Diameter (MM) |
Weight (KG) |
Minimum allowable Tensile Strength (N) | minimum allowable Crush Load
(N/100mm) |
Minimum Bending Radius (MM) |
Storage temperature (℃) |
|||
short term | long term | short term | long term | short term | long term | ||||
8/12/24 | 7.0±0.3 | 45 | 1000 | 600 | 3000 | 1000 | 20D | 10D | -20 ~~ +70 |
MPO&MTP Optical Characteristics
Item |
Parameter |
Reference |
|||
Single mode | Multimode | ||||
Standard | Elite | Standard | Elite | ||
Insertion loss |
Typical≤0.30dB Max≤0.75dB | Typical≤0.15dB Max≤0.35dB | Typical≤0.50dB Max≤0.25dB | Typical≤0.10dB Max≤0.35dB |
IEC 61300-3-34 |
Return loss | ≥ 50dB (PC)
≥ 60dB (APC) |
≥ 55dB (PC)
≥ 65dB (APC) |
≥30dB(PC) | ≥30dB(PC) | IEC 61300-3-6 |
LC/SC/FC/ST Optical Characteristics
Item |
Parameter |
Reference |
|
Single mode | Multimode | ||
Insertion loss | Typical value≤0.15dB;Maximum≤0.30 | Typical value≤0.15dB;Maximum≤0.30 | IEC 61300-3-34 |
Return loss |
≥ 60dB (APC);
≥ 50dB (UPC) |
≥30dB (UPC) |
IEC 61300-3-6 |
LC/SC/FC/ST End-Face Geometry
Item | UPC (Ref: IEC 61755-3-1) | APC (Ref: IEC 61755-3-2) |
Radius of curvature (mm) | 10 to 25 | 5 to 12 |
Fiber height (nm) | -100 to 100 | -100 to 100 |
Apex offset (μm) | 0 to 50 | 0 to 50 |
APC angle (°) | / | 8° ±0.2° |
Key error (°) | / | 0.2° max |
MPO&MTP End-Face Geometry
Ferrule parameter |
IEC-61300–3-30 | |||
Minimum | Maximum | |||
ROC |
ROC-X: | 2000mm | ∞ | |
ROC-Y: | 50mm | ∞ | ||
Angle |
Angle-X: | -0.2° | 0.2° | |
Angle-Y: |
PC | -0.2° | 0.2° | |
APC | 7.85° | 8.15° | ||
Fiber Hight: | 1000nm | 3500nm | ||
Max.DH.All: | -300nm | 300nm | ||
DH.Adj: | -300nm | 300nm | ||
DH.Ave Fiber: | -300nm | 300nm | ||
Core Dip: |
MM | -200nm | 300nm | |
SM | N/A | N/A | ||
Ferrule height | 7.9mm | 8.05mm |
End-Face Qualty (SM)
Zone | Range (μm) | Scratches | Defects | Reference |
A: Core | 0 to 25 | None | None |
IEC 61300-3-35:2015 |
B: Cladding | 25 to 115 | None | None | |
C: Adhesive | 115 to 135 | None | None | |
D: Contact | 135 to 250 | None | None | |
E: Rest of ferrule | None | None |
End-Face Qualty (MM)
Zone | Range (μm) | Scratches | Defects | Reference |
A: Core | 0 to 65 | None | None |
IEC 61300-3-35:2015 |
B: Cladding | 65 to 115 | None | None | |
C: Adhesive | 115 to 135 | None | None | |
D: Contact | 135 to 250 | None | None | |
E: Rest of ferrule | None | None |
Mechanical Characteristics
Test | Conditions | Reference |
Endurance | 500 matings | IEC 61300-2-2 |
Vibration | Frequency: 10 to 55Hz, Amplitude: 0.75mm | IEC 61300-2-1 |
Cable retention | 400N (main cable); 50N (connector part) | IEC 61300-2-4 |
Strength of coupling mechanism | 80N for 2 to 3mm cable | IEC 61300-2-6 |
Cable torsion | 15N for 2 to 3mm cable | IEC 61300-2-5 |
Fall | 10 drops, 1m drop height | IEC 61300-2-12 |
Static lateral load | 1N for 1h (main cable); 0.2N for 5min (ranch part) | IEC 61300-2-42 |
Cold | -25°C, 96h duration | IEC 61300-2-17 |
Dry heat | +70°C, 96h duration | IEC 61300-2-18 |
Change of temperature | -25°C to +70°C, 12 cycles | IEC 61300-2-22 |
Humidity | +40°C at 93%, 96h duration | IEC 61300-2-19 |
https://mefiberoptic.com/product/odvampomtp-outdoor-cable-assemblies/
Enid –
Efficient and hassle-free setup with these MPO/MTP patch cords.
Krystal –
Excellent choice for fiber optic projects, these MPO/MTP patch cords are reliable.
Tremaine –
Outstanding signal integrity with these MPO/MTP patch cords.