12 Core MPO MTP To LC Harnesses Cables
12 Core MPO MTP To LC Harnesses Cables are used to fan out the XX core MPO/MTP fibers into generic connectors, usually it is MPO/MTP to LC, but we can also make it MPO/MTP to SC/ST, FC, MTRJ, E2000, etc. The MPO/MTP harness cable is used to transit from backbone trunk cables to fiber management racks, cable jackets available are Mini-Core Plenum (OFNP), Mini-Core Riser (OFNR), Mini-Core Low Smoke Zero Halogen (LSZH), typical optical fiber types are single mode OS2, multimode OM1, OM2, OM3, OM4, OM5. The MPO/MTP to LC harness cables can be made with 2mm or 3mm ruggedized furcation legs in customized length, this will hep make it more rugged.
MPO/MTP Harnesses Cables Specification
Application
- Data communication network.
- Optical System Access network.
- Storage area networking fiber channel.
- High density architectures.
Features
- 100% pre-terminated and tested in factory to ensure transfer performance.
- Rapid configuration and networking, reduce installation time.
- Supports 40G and 100G network
- Cable Jacket material: LSZH, OFNR, OFNP
- Supports up to 12F, 24F, 48F, 72F, 96F, 144F, customized products are
Dimensional Diagrams
- MPO/MTP Harnesses Cables
Patch cord versions
Jumper tolerance requirement | |
Overall length (L) (M) | length of tolerance(CM) |
0<L≤20 | +10/-0 |
20<L≤40 | +15/-0 |
L>40 | +0.5%L/-0 |
Cable Structure
Cable Parameters
Fiber account |
OD(mm) |
Nominal Weight (kg/km) |
Max.tensile Strength(N) |
Max.Crush Resistance (N/100mm) |
Min.Bending Radius(mm) | |||
Short-term | Long-term | Short-term | Long-term | Dynamic | Static | |||
12 | 3.0±0.15 | 7.0 | 180 | 90 | 500 | 150 | 20D | 10D |
MPO&MTP Optical Characteristics
Item |
Parameter |
Reference |
|||
Single mode | Multimode | ||||
Standard | Elite | Standard | Elite | ||
Insertion loss | Typical≤0.30dB
Max≤0.75dB |
Typical≤0.15dB
Max≤0.35dB |
Typical≤0.50dB
Max≤0.25dB |
Typical≤0.10dB
Max≤0.35dB |
IEC 61300-3-34 |
Return loss | ≥ 50dB (PC)
≥ 60dB (APC) |
≥ 55dB (PC)
≥ 65dB (APC) |
≥30dB(PC) | ≥30dB(PC) | IEC 61300-3-6 |
LC/SC/FC/ST Optical Characteristics
Item |
Parameter |
Reference |
|
Single mode | Multimode | ||
Insertion loss | Typical value≤0.15dB;Maximum≤0.30 | Typical value≤0.15dB;Maximum≤0.30 | IEC 61300-3-34 |
Return loss | ≥ 60dB (APC);
≥ 50dB (UPC) |
≥30dB (UPC) | IEC 61300-3-6 |
End-Face Geometry
Item | UPC (Ref: IEC 61755-3-1) | APC (Ref: IEC 61755-3-2) |
Radius of curvature (mm) | 10 to 25 | 5 to 12 |
Fiber height (nm) | -100 to 100 | -100 to 100 |
Apex offset (μm) | 0 to 50 | 0 to 50 |
APC angle (°) | / | 8° ±0.2° |
Key error (°) | / | 0.2° max |
End-Face Geometry
Ferrule parameter |
IEC-61300–3-30 | |||
Minimum | Maximum | |||
ROC |
ROC-X: | 2000mm | ∞ | |
ROC-Y: | 50mm | ∞ | ||
Angle |
Angle-X: | -0.2° | 0.2° | |
Angle-Y: |
PC | -0.2° | 0.2° | |
APC | 7.85° | 8.15° | ||
Fiber Hight: | 1000nm | 3500nm | ||
Max.DH.All: | -300nm | 300nm | ||
DH.Adj: | -300nm | 300nm | ||
DH.Ave Fiber: | -300nm | 300nm | ||
Core Dip: |
MM | -200nm | 300nm | |
SM | N/A | N/A | ||
Ferrule height | 7.9mm | 8.05mm |
End-Face Qualty (SM)
Zone | Range (μm) | Scratches | Defects | Reference |
A: Core | 0 to 25 | None | None |
IEC 61300-3-35:2015 |
B: Cladding | 25 to 115 | None | None | |
C: Adhesive | 115 to 135 | None | None | |
D: Contact | 135 to 250 | None | None | |
E: Rest of ferrule | None | None |
End-Face Qualty (MM)
Zone | Range (μm) | Scratches | Defects | Reference |
A: Core | 0 to 65 | None | None |
IEC 61300-3-35:2015 |
B: Cladding | 65 to 115 | None | None | |
C: Adhesive | 115 to 135 | None | None | |
D: Contact | 135 to 250 | None | None | |
E: Rest of ferrule | None | None |
Mechanical Characteristics
Test | Conditions | Reference |
Endurance | 500 matings | IEC 61300-2-2 |
Vibration | Frequency: 10 to 55Hz, Amplitude: 0.75mm | IEC 61300-2-1 |
Cable retention | 400N (main cable); 50N (connector part) | IEC 61300-2-4 |
Strength of coupling mechanism | 80N for 2 to 3mm cable | IEC 61300-2-6 |
Cable torsion | 15N for 2 to 3mm cable | IEC 61300-2-5 |
Fall | 10 drops, 1m drop height | IEC 61300-2-12 |
Static lateral load | 1N for 1h (main cable); 0.2N for 5min (ranch part) | IEC 61300-2-42 |
Cold | -25°C, 96h duration | IEC 61300-2-17 |
Dry heat | +70°C, 96h duration | IEC 61300-2-18 |
Change of temperature | -25°C to +70°C, 12 cycles | IEC 61300-2-22 |
Humidity | +40°C at 93%, 96h duration | IEC 61300-2-19 |
https://mefiberoptic.com/product/mpo-mtp-harnesses-cables-specification-48core-2-0mm/
Orion –
Easy to install and integrate with our existing network using these MPO/MTP patch cords.
Emmalee –
Highly satisfied with the performance and quality of these MPO/MTP patch cords.
Nat –
Excellent for high-speed data transfer, these MPO/MTP cable assemblies are reliable.