SC/APC 12 Core (Fiber) Pigtail SM 9/125 900um 3 Meters 12 Color

(3 customer reviews)

$14.00

SC/APC 12 Core (Fiber) Pigtail SM 9/125 900um 3 Meters 12 Color with competitive price.We supply quality SC/APC 6 Core (Fiber) Pigtail SM 9/125 that are 3 meters long with 900um outer jacket. Ideal for fusion splicing.We also offer custom-made specification pigtails

Description

What Is SC/APC 12 Core (Fiber) Pigtail SM 9/125 900um 3 Meters 12 Color ?

SC/APC 12 Core (Fiber) Pigtail SM 9/125 900um 3 Meters 12 Color with competitive price.We supply quality SC/APC 6 Core (Fiber) Pigtail SM 9/125 that are 3 meters long with 900um outer jacket. Ideal for fusion splicing.We also offer custom-made specification pigtails, please contact us for details.A fiber pigtail is a specific hardware connection used for cable termination. On a fiber pigtail, one end of the wire is simply exposed fiber and the other end has a per-installed connector on it. Fiber pigtails are commonly spliced onto individual strands of a multi-fiber trunk cable.

SC/APC 12 Core (Fiber) Pigtail SM 9/125 900um 3 Meters 12 Color

SC/APC 12 Core (Fiber) Pigtail SM 9/125 900um 3 Meters 12 Color

Pigtails. A fiber pigtail is a single, short, usually tight-buffered, optical fiber that has an optical connector per-installed on one end and a length of exposed fiber at the other end. The end of the pigtail is stripped and fusion spliced to a single fiber of a multi-fiber trunk.

Fiber optic pigtail is a fiber optic cable terminated with a factory-installed connector on one end, leaving the other end terminated. Hence the connector side can be linked to equipment and the other side melted with optical fiber cables.

Features of SC/APC 12 Core (Fiber) Pigtail SM 9/125 900um 3 Meters 12 Color :

1) Superior qualified standard PC, APC, UPC, SPC polishing;
2) 100% optic test: Insertion Loss: ≤0.3 (PC); ≤0.2 (APC); ≤0.2 (UPC); ≤0.3 (SPC);
3) 100% optic test: Return Loss: ≥45 (PC); ≥60 (APC); ≥55 (UPC); ≥50 (SPC);
4) φ0.9mm, φ2.0mm, φ3.0mm cable optional;
5) Single mode (9125) or multi mode (50/125 or 62.5/125) fiber available;
6) FC, SC, LC, MU, ST, MT-RJ, etc connector
7) Simplex and duplex connector available; 8) Good exchange ability and good durability;
9) Available in fiber bunch, ribbon fan-out, pigtail available;
10) Meets ISO9001, ROHS and Bell core GR 326-core standards;
11) Customized specifications are welcomed.

Applications:

1) CATV, metro test equipment;
2) Telecommunication networks;
3) Local area networks (LAN);
4) Wide area networks (WAN);
5) Premise installations;
6) Data processing networks;
7) Video and military active device termination.

OS2

single mode fibers are only compliant with ITU-T G.652C or ITU-T G.652D standards, which means OS2 is explicitly applied to the low-water-peak fibers. These low-water-peak fibers are usually used for CWDM (Coarse Wavelength Division Multiplexing) applications.

Singlemode vs multimode

Single mode vs multimode OM1 , OM2 , OM3 , OM4 , OM5 , OS1 , OS2

 

OM4 40 100Gb 50 125 Multimode Bend Insensitive Fiber Optic Cable Structure

Bend Insensitive Fiber Optic Cable Structure A unique refractive trench with low refractive index glass layer in BIF, which reduces in light dispersion upon twisting and bending, ensuring network transmission stably and fast.

PVC Vs LSZH Vs OFNP Cable Jacket

PVC vs LSZH vs OFNP Cable Jacket

2.0mm vs 3.0mm Cable Diameter

2.0mm vs 3.0mm Indoor Fiber Optic Cable Diameter

Quality production Stages For Fiber Optic Pigtail or Fiber Pigtail Assembly

So what should be taken into consideration when choosing a ‘good’ product? What are the features that one should look for that defines the quality of any connector or jumper assembly? In order to appreciate the significance of a standard compliant product, one must first understand the process of actually making an optical connector assembly and the potential problems that could occur at each of the stages.

Production Process Fiber Patch Cord or Fiber Optic Patch Cable or Fiber Optic jumper cables

There are three main processes in the termination of a Fiber Optic Pigtail or Fiber Pigtail Assembly, Preparation, Termination and Polishing and a total of 15 steps where negligence at any one of the steps will result in an inferior jumper assembly. Each process consists of small steps, and each step requires strict Quality Control of not only the equipment used, but also how each step is carried out.

preparation of fiber cable

  1. Stripping of outer cable jacket
  2. trimming of kevlar fibers to length
  3. Stripping of 900um buffer
  4. clean bare fiber
  5. check fiber for damage
  6. mix two part epoxy
  7. degas epoxy
  8. check ferule id

termination of fiber cable

  1. inject epoxy and insert fiber
  2. crimp kevlar to back post
  3. crimp outer jacket
  4. cure connector in oven

polishing of connector end face

  1. cleave fiber
  2. Remove excess epoxy by hand or machine
  3. polish end-face by grinding machine

Quality control steps For SC/APC 12 Core (Fiber) Pigtail SM 9/125 900um 3 Meters 12 Color

Comprehensive performance testing makes sure the cable work more secure and data transmission more reliable and stable in your network.

OM4 40 100Gb 50 125 Multimode patch cable test process

1-End-Face Inspection

End-Face Inspection Evidently, fiber end-face defects like scratches, pits, cracks, and particle contamination will have a direct impact on the performance, contributing to poor insertion/return loss. Any irregularity that impedes light transmission from one fiber to the other will negatively affect IL and RL.Inspect the connector end face for scratches, defects and contamination to ensure reliable fiber connections.
Dirty Clean Fiber Optic Patch Cord

2-Insertion Loss Testing

Insertion Loss Testing In telecommunications, insertion loss refers to the loss of signal power, calculated as a ratio in dB (decibel), resulting from inserting a device in a transmission line or optical fiber. It can also be referred to as attenuation, which indicates how much the signal loss is by comparing the input power to the output power. A lower insertion loss value indicates a better insertion loss performance. For example, an insertion loss of 0.3dB is better than 0.5dB.

3-Return Loss Testing

Return Loss Testing When a signal is transmitted through a transmission line, some signal power is always reflected or returned to the source due to discontinuities in the transmission line. The discontinuity can be a mismatch with the terminating load or with a device inserted in the line. Return loss refers to the loss of reflected signal power. Therefore, the higher the return loss is, the lower the amount of reflection will be. That is to say, the fiber connector will have better performance with a higher value of RL.

4-3D Interferometer Testing

3D Interferometer Testing Test connectors or ferrules of cables to ensure that radius of curvature, the apex offset and fiber height can meet and exceed industry standards.

SC/UPC 6 Core (Fiber) Pigtail OM3 MM 50/125 Fan-out Jacketed

We supply the SC UPC fiber optic cables and connectors, adapters, attenuators. SC/UPC is used in multi media, CATV, and premise installation.SC Pigtail Multimode

SC/APC 12 Core (Fiber) Pigtail SM 9/125 900um 3 Meters 12 Color

wiki

5/5 - (2 votes) Please Rate , Thank you ☺️
Additional information
Connector Type

SC

Fiber Mode

Single Mode

Fiber Type

SM G.652D 9/125 OS2

,

SM G.657A1 9/125 OS2

,

SM G.657A2 9/125 OS2

,

SM G.657B3 9/125 OS2

,

SM NZ G.655 9/125

Fiber Count

12 Fiber

Cable Diameter

0.9mm

Polish Type

APC

Cable Jacket

LSZH

HS Code

85367000

Brand

OEM

Reviews (3)

3 reviews for SC/APC 12 Core (Fiber) Pigtail SM 9/125 900um 3 Meters 12 Color

  1. Kennedy

    Great product, highly recommend these pigtails!

  2. Breanna

    Superior build quality ensures minimal maintenance for these pigtails.

  3. Judy

    Perfect for upgrading our fiber network with these pigtails.

Add a review

Your email address will not be published. Required fields are marked *

Downloads