ODVA (MPO&MTP) Outdoor Fiber Optic Cable Assemblies

(3 customer reviews)

$8.00

ODVA (MPO & MTP) Outdoor Fiber Optic Cable Assemblies Specification IP37/IP68 outdoor waterproof IP-Series ODVA MPO MTP patch cable Assembly for Multi-purpose Outdoor , For connection between distribution ,Deployment in Remote Radio Head cell towerbox and RRH

WhatsAppWeChatSkype
Description

ODVA (MPO&MTP) Outdoor Fiber Optic Cable Assemblies

ODVA (MPO & MTP) Outdoor Fiber Optic Cable Assemblies Specification IP37/IP68 outdoor waterproof IP-Series ODVA MPO MTP patch cable Assembly for Multi-purpose Outdoor , For connection between distribution ,Deployment in Remote Radio Head cell towerbox and RRH

Application

  1. Multi-purpose Outdoor.
  2. For connection between distribution box and RRH.
  3. 3.Deployment in Remote Radio Head cell tower

Features

  1. Cost effective solution for in house termination.
  2. Low insertion loss and added loss.
  3. Height of
  4. IP67 water, dust proof and corrosion resistant
  5. The material in the jumpel cable are all-weather and UV-resistant.
  6. Mechanical performance: IEC 61754-7 standard.
  7. RoHS and REACH materials compliant.

Dimensional Diagrams

  1. ODVA(MPO&MTP) Outdoor Cable Assemblies

 

ODVA (MPO&MTP) Outdoor Fiber Optic Cable Assemblies

ODVA (MPO&MTP) Outdoor Fiber Optic Cable Assemblies

 

  1. ODVA(MPO&MTP) Outdoor Cable Assemblies

 

ODVA (MPO&MTP) Outdoor Fiber Optic Cable Assemblies

ODVA (MPO&MTP) Outdoor Fiber Optic Cable Assemblies

Patch cord versions 

Jumper tolerance requirement
Overall length (L)  M length of toleranceCM
0<L≤20 +10/-0
20<L≤40 +15/-0
L>40 +0.5%L/-0

 

Cable Structure

ODVA (MPO&MTP) Outdoor Fiber Optic Cable Assemblies

ODVA (MPO&MTP) Outdoor Fiber Optic Cable Assemblies

Cable Parameters

 

 

 

Cable Count

 

 

Out sheath Diameter

(MM)

 

 

Weight

(KG)

Minimum allowable Tensile Strength (N) minimum allowable Crush Load

(N/100mm)

Minimum Bending Radius (MM)  

 

Storage temperature

(℃)

short term long term short term long term short term long term
8/12/24 7.0±0.3 35 600 250 800 300 20D 10D -20 ~~ +70

 

Cable Structure

ODVA (MPO&MTP) Outdoor Fiber Optic Cable Assemblies

ODVA (MPO&MTP) Outdoor Fiber Optic Cable Assemblies

Cable Parameters

 

 

 

Cable Count

 

 

Out sheath Diameter

(MM)

 

 

Weight

(KG)

Minimum allowable Tensile Strength (N) minimum allowable Crush Load

(N/100mm)

Minimum Bending Radius (MM)  

 

Storage temperature

(℃)

short term long term short term long term short term long term
8/12/24 7.0±0.3 45 1000 600 3000 1000 20D 10D -20 ~~ +70

 

MPO&MTP Optical Characteristics

 

 

 

Item

Parameter  

 

Reference

Single mode Multimode
Standard Elite Standard Elite
 

Insertion loss

Typical≤0.30dB Max≤0.75dB Typical≤0.15dB Max≤0.35dB Typical≤0.50dB Max≤0.25dB Typical≤0.10dB Max≤0.35dB  

IEC 61300-3-34

Return loss ≥ 50dB (PC)

≥ 60dB (APC)

≥ 55dB (PC)

≥ 65dB (APC)

≥30dB(PC) ≥30dB(PC) IEC 61300-3-6

 

LC/SC/FC/ST Optical Characteristics 

 

Item

Parameter  

Reference

Single mode Multimode
Insertion loss Typical value≤0.15dB;Maximum≤0.30 Typical value≤0.15dB;Maximum≤0.30 IEC 61300-3-34
 

Return loss

≥ 60dB (APC);

≥ 50dB (UPC)

≥30dB (UPC)  

IEC 61300-3-6

 

LC/SC/FC/ST End-Face Geometry 

Item UPC (Ref: IEC 61755-3-1) APC (Ref: IEC 61755-3-2)
Radius of curvature (mm) 10 to 25 5 to 12
Fiber height (nm) -100 to 100 -100 to 100
Apex offset (μm) 0 to 50 0 to 50
APC angle (°) / 8° ±0.2°
Key error (°) / 0.2° max

 

MPO&MTP End-Face Geometry 

 

Ferrule    parameter

IEC-61300–3-30
Minimum Maximum
 

ROC

ROC-X: 2000mm
ROC-Y: 50mm
 

Angle

Angle-X: -0.2° 0.2°
 

Angle-Y:

PC -0.2° 0.2°
APC 7.85° 8.15°
Fiber Hight: 1000nm 3500nm
Max.DH.All: -300nm 300nm
DH.Adj: -300nm 300nm
DH.Ave Fiber: -300nm 300nm
 

Core Dip:

MM -200nm 300nm
SM N/A N/A
Ferrule    height 7.9mm 8.05mm

 

End-Face Qualty (SM)

 

Zone Range (μm) Scratches Defects Reference
A: Core 0 to 25 None None  

 

 

 

IEC 61300-3-35:2015

B: Cladding 25 to 115 None None
C: Adhesive 115 to 135 None None
D: Contact 135 to 250 None None
E: Rest of ferrule None None

 

End-Face Qualty (MM)

 

Zone Range (μm) Scratches Defects Reference
A: Core 0 to 65 None None  

 

 

 

 

IEC 61300-3-35:2015

B: Cladding 65 to 115 None None
C: Adhesive 115 to 135 None None
D: Contact 135 to 250 None None
E: Rest of ferrule None None

 

Mechanical Characteristics 

Test Conditions Reference
Endurance 500 matings IEC 61300-2-2
Vibration Frequency: 10 to 55Hz, Amplitude: 0.75mm IEC 61300-2-1
Cable retention 400N (main cable); 50N (connector part) IEC 61300-2-4
Strength of coupling mechanism 80N for 2 to 3mm cable IEC 61300-2-6
Cable torsion 15N for 2 to 3mm cable IEC 61300-2-5
Fall 10 drops, 1m drop height IEC 61300-2-12
Static lateral load 1N for 1h (main cable); 0.2N for 5min (ranch part) IEC 61300-2-42
Cold -25°C, 96h duration IEC 61300-2-17
Dry heat +70°C, 96h duration IEC 61300-2-18
Change of temperature -25°C to +70°C, 12 cycles IEC 61300-2-22
Humidity +40°C at 93%, 96h duration IEC 61300-2-19

wiki

https://mefiberoptic.com/product/odvampomtp-outdoor-cable-assemblies/

4.7/5 - (12 votes) Please Rate , Thank you ☺️
Additional information
Brand

OEM

Reviews (3)

3 reviews for ODVA (MPO&MTP) Outdoor Fiber Optic Cable Assemblies

  1. Enid

    Efficient and hassle-free setup with these MPO/MTP patch cords.

  2. Krystal

    Excellent choice for fiber optic projects, these MPO/MTP patch cords are reliable.

  3. Tremaine

    Outstanding signal integrity with these MPO/MTP patch cords.

Add a review

Your email address will not be published. Required fields are marked *

Downloads