ODVA (MPO & MTP®) Outdoor Fiber Optic Cable Assemblies
$8.00
ODVA (MPO & MTP®) Outdoor Fiber Optic Cable Assemblies Specification IP37/IP68 outdoor waterproof IP-Series ODVA MPO MTP® patch cable Assembly for Multi-purpose Outdoor , For connection between distribution ,Deployment in Remote Radio Head cell towerbox and RRH
ODVA (MPO & MTP®) Outdoor Fiber Optic Cable Assemblies
ODVA (MPO & MTP®) Outdoor Fiber Optic Cable Assemblies Specification IP37/IP68 outdoor waterproof IP-Series ODVA MPO MTP® patch cable Assembly for Multi-purpose Outdoor , For connection between distribution ,Deployment in Remote Radio Head cell towerbox and RRH

ODVA (MPO & MTP®) Outdoor Fiber Optic Cable Assemblies
Application ODVA (MPO & MTP®) Outdoor Fiber Optic Cable Assemblies
- Multi-purpose Outdoor.
- For connection between distribution box and RRH.
- Deployment in Remote Radio Head cell tower
Features
- Factory terminated (tested cables) or Field uninstallable version available .
- Low insertion loss and added loss.
- Height of
- IP67 water, dust proof and corrosion resistant
- Plug has tolerance free design, free floating on Z-axis.
- The material in the jumper cable are all-weather and UV-resistant. 7.Mechanical performance: IEC 61754-7 standard.
- RoHS and REACH materials compliant.
- 100% Compatible with FullAXS Connectors and has site technical features.
Dimensional Diagrams of ODVA (MPO & MTP®) Outdoor Fiber Optic Cable Assemblies
- IPFX(MPO&MTP®) Outdoor Cable Assemblies

IPFX ODVA (MPO & MTP®) Outdoor Fiber Optic Cable Assemblies
- IPFX(MPO&MTP®) Outdoor Cable Assemblies

ODVA (MPO & MTP®) Outdoor Fiber Optic Cable Assemblies
Patch cord versions
| Jumper tolerance requirement | |
| Overall length (L) (M) | length of tolerance(CM) |
| 0<L≤20 | +10/-0 |
| 20<L≤40 | +15/-0 |
| L>40 | +0.5%L/-0 |
Cable Structure

ODVA (MPO & MTP®) Outdoor Fiber Optic Cable Assemblies
Cable Parameters
Cable Structure
Cable Parameters MPO&MTP® ptical Characteristics LC/SC/FC/ST Optical Characteristics LC/SC/FC/ST End-Face Geometry MPO&MTP® End-Face Geometry End-Face Qualty (SM) End-Face Qualty (MM) Mechanical Characteristics
|
Cable Count |
Out sheath Diameter (MM) |
Weight (KG) |
Minimum allowable Tensile Strength (N) | minimum allowable Crush Load
(N/100mm) |
Minimum Bending Radius (MM) |
Storage temperature (℃) |
|||
|
short term |
long term |
short term |
long term |
short term |
long term |
||||
| 8/12/24 | 7.0±0.3 | 35 | 600 | 250 | 800 | 300 | 20D | 10D | -20 ~~ +70 |
|
Cable Count |
Out sheath Diameter (MM) |
Weight (KG) |
Minimum allowable Tensile Strength (N) | minimum allowable Crush Load
(N/100mm) |
Minimum Bending Radius (MM) |
Storage temperature (℃) |
|||
| short term | long term | short term | long term | short term | long term | ||||
| 8/12/24 | 7.0±0.3 | 45 | 1000 | 600 | 3000 | 1000 | 20D | 10D | -20 ~~ +70 |
|
Item |
Parameter |
Reference |
|||||||
| Single mode | Multimode | ||||||||
| Standard | Elite | Standard | Elite | ||||||
|
Insertion loss |
Typical≤0.30dB Max≤0.75dB | Typical≤0.15dB Max≤0.35dB | Typical≤0.50dB Max≤0.25dB | Typical≤0.10dB Max≤0.35dB |
IEC 61300-3-34 |
||||
| Return loss | ≥ 50dB (PC)
≥ 60dB (APC) |
≥ 55dB (PC)
≥ 65dB (APC) |
≥30dB(PC) | ≥30dB(PC) | IEC 61300-3-6 | ||||
|
Item |
Parameter |
Reference |
|||||||
| Single mode | Multimode | ||||||||
| Insertion loss | Typical value≤0.15dB;Maximum≤0.30 | Typical value≤0.15dB;Maximum≤0.30 | IEC 61300-3-34 | ||||||
|
Return loss |
≥ 60dB (APC);
≥ 50dB (UPC) |
≥30dB (UPC) |
IEC 61300-3-6 |
||||||
| Item | UPC (Ref: IEC 61755-3-1) | APC (Ref: IEC 61755-3-2) | |||||||
| Radius of curvature (mm) | 10 to 25 | 5 to 12 | |||||||
| Fiber height (nm) | -100 to 100 | -100 to 100 | |||||||
| Apex offset (μm) | 0 to 50 | 0 to 50 | |||||||
| APC angle (°) | / | 8° ±0.2° | |||||||
| Key error (°) | / | 0.2° max | |||||||
|
Ferrule parameter |
IEC-61300–3-30 | ||||||||
| Minimum | Maximum | ||||||||
|
ROC |
ROC-X: | 2000mm | ∞ | ||||||
| ROC-Y: | 50mm | ∞ | |||||||
|
Angle |
Angle-X: | -0.2° | 0.2° | ||||||
|
Angle-Y: |
PC | -0.2° | 0.2° | ||||||
| APC | 7.85° | 8.15° | |||||||
| Fiber Hight: | 1000nm | 3500nm | |||||||
| Max.DH.All: | -300nm | 300nm | |||||||
| DH.Adj: | -300nm | 300nm | |||||||
| DH.Ave Fiber: | -300nm | 300nm | |||||||
|
Core Dip: |
MM | -200nm | 300nm | ||||||
| SM | N/A | N/A | |||||||
| Ferrule height | 7.9mm | 8.05mm | |||||||
| Zone | Range (μm) | Scratches | Defects | Reference | |||||
| A: Core | 0 to 25 | None | None |
IEC 61300-3-35:2015 |
|||||
| B: Cladding | 25 to 115 | None | None | ||||||
| C: Adhesive | 115 to 135 | None | None | ||||||
| D: Contact | 135 to 250 | None | None | ||||||
| E: Rest of ferrule | None | None | |||||||
| Zone | Range (μm) | Scratches | Defects | Reference | |||||
| A: Core | 0 to 65 | None | None |
IEC 61300-3-35:2015 |
|||||
| B: Cladding | 65 to 115 | None | None | ||||||
| C: Adhesive | 115 to 135 | None | None | ||||||
| D: Contact | 135 to 250 | None | None | ||||||
| E: Rest of ferrule | None | None | |||||||
| Test | Conditions | Reference | |||||||
| Endurance | 500 matings | IEC 61300-2-2 | |||||||
| Vibration | Frequency: 10 to 55Hz, Amplitude: 0.75mm | IEC 61300-2-1 | |||||||
| Cable retention | 400N (main cable); 50N (connector part) | IEC 61300-2-4 | |||||||
| Strength of coupling mechanism | 80N for 2 to 3mm cable | IEC 61300-2-6 | |||||||
| Cable torsion | 15N for 2 to 3mm cable | IEC 61300-2-5 | |||||||
| Fall | 10 drops, 1m drop height | IEC 61300-2-12 | |||||||
| Static lateral load | 1N for 1h (main cable); 0.2N for 5min (ranch part) | IEC 61300-2-42 | |||||||
| Cold | -25°C, 96h duration | IEC 61300-2-17 | |||||||
| Dry heat | +70°C, 96h duration | IEC 61300-2-18 | |||||||
| Change of temperature | -25°C to +70°C, 12 cycles | IEC 61300-2-22 | |||||||
| Humidity | +40°C at 93%, 96h duration | IEC 61300-2-19 | |||||||